Thursday, May 21, 2009

Biggest Boobs Heroine

Climate: Midea, a new range of air conditioners


MIDEA, range of R410A air conditioners, single and multi split systems, both ON / OFF and drive, mostly in Class A and good value for money. Prices from € 196. Only from Varese Frigor.

Saturday, May 9, 2009

Marcin Sarnek Gliwice

Climate: begins summer for air conditioning.


By now the summer season 'just outside el' industry for packaging household and small business has already 'forward new proposals for the 2009 season. They, like now already 'done for some years, are concentrated in the direction of energy saving, in an increase in cooling capacity and optimization of components for performance more and more 'high with lower consumption.

Coolers

The need to obtain significant values \u200b\u200bon energy efficiency ratio (EER) performance improvement has led to extremes of heat exchangers. With the same 'geometry of space were taken exchanger unit' internal parts (meets C or V) that would dramatically increase the exchange surface. The adoption of fans with larger diameter and specific shape to optimize the air flow has led to an increase in the overall performance of the machine. In addition, the increase in the diameter impeller has allowed the reduction of speed 'fan will achieve greater quietness' of operation equal' air flow Treaty
Also with regard to the heat exchanger unit 'outside there have been improvements as regards' exchange efficiency, a fact which has resulted in increases to 20% of the overall efficiency of the air conditioner. The same
and 'reports on the construction, for which there have been steps forward. Special machining have led to finned particularly resistant to weathering and therefore more 'durable. The best time keeps in the years optimal energy efficiency for the heat exchanger. so 'as to the units' internal for units 'are registered outside news' in the fans, especially in their aerodynamic profile that allows for better air flow, reducing turbulence and turbo.
mail is more and more 'attention to the quality' of the air exit from 'inside. Through the use of special air filters is treated in private all the particles and smells that may make it less pleasant to stay in air-conditioned room. In particular, we used anti-dust filters, activated carbon filters to absorb odors and special filters, electrostatic action to restrain dust, pollen, bacteria, viruses and other contaminants. Purifying filters are also used as filters to the catechin, can absorb odors due to smoke.
The action of filters and 'also aimed to eliminate the smell caused by volatile organic chemicals used as components in the construction of civil building and the smell of cigarette smoke.
To increase the welfare conditions within the room air conditioners are offered with ionizers, can emit negative particles within the environment that help to create a microclimate relaxing.

Compressors

Again in order to reduce consumption and improve energy efficiency, are widely used rotary scroll compressors and dual-rotor, which are optimized in terms of mechanical and electrical components.
The inverter control allows for energy savings, and will quickly reach the set temperature. When you turn on the high frequency inverter system is operating permits to increase the cooling capacity and reduce, even in the middle 'than the traditional time, the time necessary to achieve the desired temperature. Once you have reached this temperature the operating frequency decreases, allowing you to maintain constant its value with very small fluctuations. Next to the inverter technology is
proposed a two-cylinder compressor in which each cylinder and 'connected to the other three joints, as shown in Figure 2. Through them, the refrigerant passes through the intervention of three independent electronic valves that allow such 'have different levels of output power, 25 to 100%, depending on their state of opening or closing. Together with the use of electronic expansion valves, with this system and 'conveniently possible to adjust the cooling capacity.

Refrigerants

All manufacturers now offer models that work with the new fluids containing no chlorine, R410A and R407C. Recall that the characteristics of R407C are quite similar, in terms of temperature and pressure of work, to those of R22, while those of R410A are significantly different. On the other hand, the R407C and 'a mixture of a high temperature glide during state changes, and therefore requires some caution in piu' during its handling.
There are alternatives to the use of traditional refrigerants. Have been proposed, in fact, split cooling systems running on natural gas or LPG termofrigorifere beyond the use of plants and related refrigerants.

Please note that for optimal operation of your air conditioner should perform a scheduled maintenance at the beginning of the season with cleaning filters, cleaning the condenser, refrigerant gas and oil level control, control electrical components, settings and reverse winter / summer. Contact
technicians Varese Frigor we will be happy to make this task for you.